Enable Gas Transmission

7 active notices

Showing 7 notices
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Force Majeure] DELHI COMPRESSOR FMJ TERM

SEV 4/5
Restoration Until Further Notice 14 Days

Enable Gas Transmission has terminated Force Majeure Balancing Alert #6327 at its Delhi Compressor Station in Richland Parish, Louisiana, effective immediately as of April 12, 2026. The underlying unplanned maintenance event began April 8, 2026, and curtailed primary firm services including deliveries to Gulf Run Delhi Core Del (#291856). The termination notice restores capacity at this South Pooling Area location after approximately 4 days of outage.

Restoration of EGT Delhi Compressor Station primary firm capacity removes a bullish supply constraint on Haynesville/Gulf Coast flows; expect mild bearish pressure on Henry Hub and Gulf Run index as volumes reconnect to downstream Gulf Coast and LNG feed gas markets.
Reroute: Moderate: Gulf South and Kinder Morgan assets serve overlapping Haynesville and Gulf Coast corridors and would have partially absorbed displaced volumes during the outage; full capacity is now restored at Delhi, reducing pressure on alternative paths.
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Force Majeure] DELHI COMPRESSOR FMJ

SEV 4/5
Force Majeure Until Further Notice

Enable Gas Transmission declared a force majeure at its Delhi Compressor Station in Richland Parish, Louisiana, effective April 8, 2026, continuing until further notice. The unplanned outage affects EGT's South Pooling Area and eliminates deliveries to Gulf Run Delhi Core Del (#291856), with primary firm (FT) services at risk. No restoration timeline has been provided.

EGT force majeure at Delhi CS cuts primary firm service and blocks feed gas delivery to Gulf Run Delhi Core Del, a Haynesville-to-LNG corridor interconnect -- constraint keeps gas onshore and is bearish for Henry Hub and Gulf Coast basis; with no restoration timeline, downward pressure on nearby basis points persists until further notice.
Reroute: Moderate: Gulf South and Kinder Morgan assets serve overlapping Haynesville corridor routes, and Southern Natural (EGT/Energy Transfer) provides some Southeast alternative paths; however, the specific loss of the Gulf Run Delhi Core Del delivery point limits the ability to fully replace volumes destined for downstream LNG or Gulf Coast markets via that interconnect.
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Force Majeure] ALLEN COMPRESSOR FMJ

SEV 4/5
Force Majeure Until Further Notice

Enable Gas Transmission has declared force majeure at Allen Compressor Station in Hughes County, Oklahoma (West 2 Pooling Area), effective May 6, 2026, with no restoration timeline. Primary firm service through Allen CS is expected to be scheduled at only 80-90% of MRO quantities for the duration of the outage. EGT will lock nominations in the impacted area during the Evening Cycle of each affected day until further notice.

Force majeure with no end date at Allen CS tightens supply out of EGT West 2 Pooling Area in Oklahoma, with 10-20% curtailment of primary firm service creating upward basis pressure at Arkla Basin and Oklahoma points; watch Henry Hub and Gulf South Southeast basis for secondary tightening effects.
Reroute: Moderate: Gulf South (monitored) and Southern Natural (EGT via Energy Transfer, monitored) serve overlapping Arkla Basin and Southeast corridors, but no specific volume is disclosed so reroute adequacy cannot be fully assessed. Primary firm curtailments at 10-20% of MRO suggest meaningful but not catastrophic displacement.
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Maintenance] MRT FOUNTAIN HILL MAINTENANCE

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Maintenance] LINE O-1-O PIGGING PROJECT

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Maintenance] LINE AC PIG RUNS

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Maintenance] PLANNED BYARS MAINTENANCE

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.